Verti-Drain®

Overview

Specification

Standard Specifications of  Verti-Drain®

Physical & Mechanical Properties Test Methods Unit VDek-706 VD-707 VDek-806 VD-808
Drain (Core + Filter)
Core configuration
Core material PP PP PP PP
Width ASTM D 3774, ISO 22198 mm 100±5 100±5 100±5 100±5
Thickness ASTM D 5199, ISO 9863-1 mm 3.0 3.0 4.0 4.0
Tensile strength, full width ASTM D 4595, ISO 10319 kN ≥ 2.5 ≥ 2.5 ≥ 2.5 ≥ 2.5
Elongation at 0.5kN ASTM D 4595, ISO 10319 % ≤ 10 ≤ 10 ≤ 10 ≤ 10
Discharge capacity, qw, 350kPa, i=0.5 ASTM D 4716 cm³/s ≥ 80 ≥ 80 ≥ 90 ≥ 90

 

 

Filter
Wide width tensile strength, MD ASTM D 4595, ISO 10319 kN/m ≥ 7.0 ≥ 7.0 ≥ 7.0 ≥ 7.0
Grab tensile strength, MD ASTM D 4632 N ≥ 500 ≥ 500 ≥ 500 ≥ 500
Coefficient of permeability, k ASTM D 4491, ISO 11058   m/s ≥ 1×10-4 ≥ 1×10⁻4 ≥ 1×10⁻4 ≥ 1×10⁻4
Apparent opening size ASTM D 4751 (O95)

ISO 12956 (O90)

<  75 <  75 <  75 < 75
Trapezoid tear strength, MD ASTM D 4533 N ≥ 100 ≥ 100 ≥ 100 ≥ 100
Puncture resistance ASTM D 4833 N ≥ 100 ≥ 100 ≥ 100 ≥ 100
Burst strength ASTM D 3786 kPa ≥ 900 ≥ 900 ≥ 900 ≥ 900

 

Nominal Dimensions & Transportation Details
Roll length m 330 330 250 250
Outside diameter of roll – approx. m 1.10 1.10 1.10 1.10
Inside diameter of roll – approx. m 0.15 0.15 0.15 0.15
20′ loading capacity – approx. m 66,000 66,000 50,000 50,000
40′ loading capacity – approx. m 165,000 165,000 125,000 125,000

※ Notes:

1) Discharge capacity, qw, is based on index test with rigid-rigid bedding condition and calculated based on qw = Q/i x RT, where Q is the flow rate per each unit of time(m3/s), i is hydraulic gradient and RT is the temperature correction coefficient.
2) The values given are indicative and correspond to average test results obtained in our laboratory and independent authorized institutes.
3) The above information is subject to be revised according to new developments and findings.
4) Various specifications of PVD are available upon customer’s demand.