Hori-Drain®

Overview

Specification

Standard Specifications of Hori-Drain®

 

Property Unit Test standard HDEI100 HDEI200 HDIK200 HDEI300 HDIK300
Drain
(Core+Filter)
Material PP, PE, PET PP, PE, PET PP, PE, PET PP, PE, PET PP, PE, PET
Width ISO 22198,  ASTM D 3774 100 ± 5 200 ± 5 200 ± 5 300 ± 5 300 ± 5
Thickness ISO 9863-1, ASTM D 5199 ≥9.0 ≥9.0 ≥9.0 ≥9.0 ≥9.0
Configuration

(Reinforced corrugated core)

Tensile strength kN/width ISO 10319,  ASTM D 4595 ≥3.0 ≥7.0 ≥8.0 ≥9.0 ≥11.0
Discharge capacity, qw, 500kPa, i=0.1 cm3/s ASTM D 4716 ≥2,000 ≥3,300 ≥3,500 ≥5,000 ≥5,250
Filter Material PET PET PET PET PET
Grab tensile strength, MD N ASTM D 4632 ≥500 ≥500 ≥500 ≥500 ≥500
Tensile strength, MD kN/m ISO 10319,  ASTM D 4595 ≥6.0 ≥6.0 ≥6.0 ≥6.0 ≥6.0
Elongation, MD % ISO 10319,  ASTM D 4595 20~80 20~80 20~80 20~80 20~80
Tear strength, MD N ASTM D 4533 ≥70 ≥100 ≥100 ≥100 ≥100
Puncture strength N ASTM D 4833 ≥150 ≥150 ≥150 ≥150
Burst strength kPa ASTM D 3786 ≥900 ≥900 ≥900 ≥900
Permeability cm/s ISO 11058,  ASTM D 4491 ≥1 X 10-2 ≥1 X 10-2 ≥1 X 10-2 ≥1 X 10-2 ≥1 X 10-2
Opening size, O95 ASTM D 4751 ≤75 ≤75 ≤75 ≤75 ≤75

※ Notes:

1) Discharge capacity, qw, is based on index test with rigid-rigid bedding condition and calculated based on qw = Q/i x RT, where Q is the flow rate per each unit of time(m3/s), i is hydraulic gradient and RT is the temperature correction coefficient.
2) The values given are indicative and correspond to average test results obtained in our laboratory and independent authorized institutes.
3) The above information is subject to be revised according to new developments and findings.