Standard Specifications of Verti-Drain®
| Physical & Mechanical Properties | Test Methods | Unit | VDek-706 | VD-707 | VDek-806 | VD-808 | ||
| Drain (Core + Filter) | ||||||||
| Core configuration | ||||||||
| Core material | PP | PP | PP | PP | ||||
| Width | ASTM D 3774, ISO 22198 | mm | 100±5 | 100±5 | 100±5 | 100±5 | ||
| Thickness | ASTM D 5199, ISO 9863-1 | mm | 3.0 | 3.0 | 4.0 | 4.0 | ||
| Tensile strength, full width | ASTM D 4595, ISO 10319 | kN | ≥ 2.5 | ≥ 2.5 | ≥ 2.5 | ≥ 2.5 | ||
| Elongation at 0.5kN | ASTM D 4595, ISO 10319 | % | ≤ 10 | ≤ 10 | ≤ 10 | ≤ 10 | ||
| Discharge capacity, qw, 350kPa, i=0.5 | ASTM D 4716 | cm³/s | ≥ 80 | ≥ 80 | ≥ 90 | ≥ 90 | ||
| Filter | ||||||||
| Wide width tensile strength, MD | ASTM D 4595, ISO 10319 | kN/m | ≥ 7.0 | ≥ 7.0 | ≥ 7.0 | ≥ 7.0 | ||
| Grab tensile strength, MD | ASTM D 4632 | N | ≥ 500 | ≥ 500 | ≥ 500 | ≥ 500 | ||
| Coefficient of permeability, k | ASTM D 4491, ISO 11058 | m/s | ≥ 1×10-4 | ≥ 1×10⁻4 | ≥ 1×10⁻4 | ≥ 1×10⁻4 | ||
| Apparent opening size | ASTM D 4751 (O95)
ISO 12956 (O90) |
㎛ | < 75 | < 75 | < 75 | < 75 | ||
| Trapezoid tear strength, MD | ASTM D 4533 | N | ≥ 100 | ≥ 100 | ≥ 100 | ≥ 100 | ||
| Puncture resistance | ASTM D 4833 | N | ≥ 100 | ≥ 100 | ≥ 100 | ≥ 100 | ||
| Burst strength | ASTM D 3786 | kPa | ≥ 900 | ≥ 900 | ≥ 900 | ≥ 900 | ||
| Nominal Dimensions & Transportation Details | ||||||||
| Roll length | m | 330 | 330 | 250 | 250 | |||
| Outside diameter of roll – approx. | m | 1.10 | 1.10 | 1.10 | 1.10 | |||
| Inside diameter of roll – approx. | m | 0.15 | 0.15 | 0.15 | 0.15 | |||
| 20′ loading capacity – approx. | m | 66,000 | 66,000 | 50,000 | 50,000 | |||
| 40′ loading capacity – approx. | m | 165,000 | 165,000 | 125,000 | 125,000 | |||
※ Notes:
1) Discharge capacity, qw, is based on index test with rigid-rigid bedding condition and calculated based on qw = Q/i x RT, where Q is the flow rate per each unit of time(m3/s), i is hydraulic gradient and RT is the temperature correction coefficient.
2) The values given are indicative and correspond to average test results obtained in our laboratory and independent authorized institutes.
3) The above information is subject to be revised according to new developments and findings.
4) Various specifications of PVD are available upon customer’s demand.